UL 1015 18 AWG 16 Strand 105C 600V – Tinned Copper

Min/Mult: 250/50

  • UL And CSA Style TEW, MTW
  • UL Style 1015 600V 105°C
  • Ul Style 1230 600V 105°C
  • C.S.A. Type TR-32 600V 105°C
  • Passes UL VW-1 Flame Test
Clear
SKU: W10151816-T Categories: , ,

Description

APPLIANCE WIRING MATERIAL
Subj.758 Section 1 Page 1015 Issued:1959-05-01
Revised:2013-02-22
Style 1015 Single conductor with extruded insulation
Rating 80, 90 or 105 deg C, 600 Vac or 750 Vdc, Horizontal flame. Optional – 60 or 80 deg C Oil.
Conductor 30 AWG – 2000 kcmil, Solid or Stranded.
Insulation Extruded PVC
Conductor size Minimum average thickness Minimum thickness at any point
30-9 AWG 30 mils 27 mils
8-7 AWG 45 mils 40 mils
6-2 AWG 60 mils 54 mils
1-4/0 AWG 80 mils 72 mils
250-500 kcmil 95 mils 86 mils
550-1000 kcmil 110 mils 99 mils
1100-2000 kcmil 125 mils 112 mils
Standard Appliance Wiring Material UL 758.
Marking General
Use Internal Wiring of Appliances. Tags may also indicate the following: 2,500 V peak – for electronic use only.

UL and the UL Logo are trademarks of UL LLC © 2018

Additional information

Weight 0.0048 lbs
Dimensions 1 × 0.125 × 0.125 in
Amp Rating
Number of Conductors
Manufacturer Part Number
Digi-Key Part Number
Manufacturer
Cord Length
Plug Type
spool-length
Stripe Color
Style/Rating

Gauge

Conductor

Color

, , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , ,

Insulation

stranding

Temperature Rating

Voltage Rating